HNSC-C Standard
Function: The standard version of the HNSC-C series monitors tilt deviations from the horizontal around a tilt axis (X-axis). If a tilt deviation occurs on the X-axis that exceeds the defined normal condition monitoring range, a switching operation takes place.
The tilt switch will only return to its previous operating state once the tilt deviation falls below the defined switching point again.
Measuring range X-axis:
Switching point X-axis:
Accuracy:
Hysteresis:
Cut-off frequency:
Measuring principle:
-90°…+90°
Selectable tilt of 0°, 15°, 30°, or 45°
+/- 2°
2° +/- 0.5°
5 Hz
MEMS
Housing material:
Dimensions:
Plastic
40 x 20 x 20 mm
Operating voltage UB:
Rated voltage:
Ripple:
Rated current:
Standby current:
Switching output:
Static voltage drop:
Connection:
Cable length:
9-30 V DC
24 V DC
< 15 %
250 mA
<5 mA
According to customer specifications (see data sheet)
5V, max.
Cable with M12 connector, 4-pole, A-coded
2m
EU Directives:
.
Applied standards:
2014/30/EU EMC Directive
2011/65/EU RoHS Directive
EN 61000-6-3:2007 + A1:2011/ AC:2012 (Emissions for residential, commercial, and light industrial environments),
EN 61000-6-2:2005 + AC:2005-09 (Immunity for industrial environments)
MTTFd:
Service life:
2237 years (Normally open/closed), 2194 years (Changeover)
20 years
The specification of the MTTF/service life value does not constitute binding quality and/or durability commitments; it is merely based on experience without binding character.
These value specifications do not extend or otherwise influence the limitation period for warranty claims.
Downloads
PDF: Data Sheet HNSC-C Standard
CAD: Tilt Switch HNSC-C-Standard
Technical changes are reserved.