HNSC-C-K
Function: The tilt protection version of the HNSC-C series monitors rotationally symmetric tilt deviations from the vertical (Z-axis). If a tilt deviation occurs on the Z-axis that exceeds the switching angle, a switching operation takes place. The tilt switch will only return to its previous operating state once the tilt deviation falls below the defined switching angle again.
Measuring range X-axis:
Switching point X-axis:
Accuracy:
Hysteresis:
Cut-off frequency:
Measuring principle:
-90°…+90°
Selectable tilt of 45° or 90°
+/- 3°
3° +/- 1°
5 Hz
MEMS
Housing material:
Dimensions:
Plastic
40 x 24 x 20 mm
Operating voltage UB:
Rated voltage:
Ripple:
Rated current:
Standby current:
Switching output:
Static voltage drop:
Connection:
Cable length:
9-30 VDC
24 VDC
< 15 %
250 mA
<5 mA
According to customer specifications (see data sheet)
5V, max.
Cable with M12 connector, 4-pole, A-coded
2m
EU Directives:
.
Applied standards:
2014/30/EU EMC Directive
2011/65/EU RoHS Directive
EN 61000-6-3:2007 + A1:2011/ AC:2012 (Emissions for residential, commercial, and light industrial environments),
EN 61000-6-2:2005 + AC:2005-09 (Immunity for industrial environments)
MTTFd:
Service life:
2237 years (Normally open/closed), 2194 years (Changeover)
20 years
The specification of the MTTF/service life value does not constitute binding quality and/or durability commitments; it is merely based on experience without binding character.